LaCie 12big Rack Fibre 8 System Overview
User Manual page 17
1.4.2.1. Battery Module
The 12big Rack Fibre 8 RAID Controller module assembly includes
a removable backup battery module, located as shown in Fig. 09.
The battery module contains a user replaceable cell battery pack,
see Fig. 10. The battery pack provides protection of the controller
cache contents if the AC power fails. A fully charged battery should
provide up to 72 hours of protection.
The battery charging behavior is described as follows: during initial
startup, the battery charging system will enable the battery char-
ger to complete a full charge cycle. Once the charge completion
indication is detected from the charger, the charger is monitored
for an additional period of three hours for further charge activity.
If no charge activity is detected within that three hour window, the
battery is considered to be fully charged, and the charger is dis-
abled. Routinely, after every five days (7,200 minutes), the charger
is re-enabled to provide a top-off charge to the battery. Again, once
the charge completion indication is detected from the charger, the
charger is monitored for an additional period of three hours for fur-
ther charge activity. If no charge activity is detected within that three
hour window, the battery is considered to be fully charged, and the
charger is disabled until the next top-off charge interval elapses.
1.4.2.2. Fibre Channel Interface
The 12big Rack Fibre 8 RAID Controller module provides two Fibre
Channel SFP host interface connections. The controller uses two SFP
cages to capture the removable SFP optical modules. These connec-
tions are labeled Host 0 and Host 1. Please contact your supplier for
a list of qualified SFP optical components.
Each connection is bi-directional between the Fibre Channel host
side interface and the drives. The drives will not be presented to the
Host until they are configured into disk arrays and logical drives, and
then mapped by the controller.
TECHNICAL NOTE: There are no external terminators required
with Fibre Channel architecture.
IMPORTANT INFO: Optical SFP modules must be UL (or other
North American NRTL) RECOGNIZED COMPONENT and the laser
in the module must comply with Laser Class 1, US 21 CFR (J) and
EN 60825-1.
Fig. 10 - Backup Battery Module